夜间遥感场地替代定标的微光光谱仪设计与试验分析
CSTR:
作者:
作者单位:

(中国科学院空天信息创新研究院 中国科学院定量遥感信息技术重点实验室, 北京 100094)

作者简介:

张 宇(1994-),女,硕士,助理研究员,研究方向为微光夜视、夜间遥感辐射定标与应用;

通讯作者:

中图分类号:

TP702

基金项目:

国家重点研发计划项目(2018YFB0504600,2018YFB0504604,2018YF0504800,2018YF0504805);中科院前沿科学重点研发项目(QYZDB-SSW-JSC051).*通信作者:邱实E-mail:qiushi@aircas.ac.cn


Design and Experimental Analysis of Low-level Light Spectrometer for Nighttime Remote Sensing Sites Vicarious Calibration
Author:
Affiliation:

(Chinese Academy of Sciences Key Laboratory of Quantitative Remote Sensing Information Technology, Chinese Academy of Sciences, Aerospace Information Research Institute, Beijing 100094, CHN)

Fund Project:

  • 摘要
  • |
  • 图/表
  • |
  • 访问统计
  • |
  • 参考文献
  • |
  • 相似文献
  • |
  • 引证文献
  • |
  • 资源附件
  • |
  • 文章评论
    摘要:

    针对目前传统的地物光谱仪对光信号强度要求较高,只能白天使用,无法在夜间使用而导致夜间遥感在轨辐射定标不确定度较高的问题,提出一种将传统光谱仪的CCD(Charge-Coupled Device)探测器与像增强器直接耦合提升光谱仪低照度条件下信息获取能力的技术方案。基于该技术方案的光谱仪可有效实现地面目标光谱信息的夜间测量。相关测试试验结果表明:在入射光源只有月光和星光的条件下,该微光光谱仪可有效实现对地面目标光谱信息的测量,且性能良好稳定,未来可应用于夜间遥感定标、夜间目标光谱信息获取等应用领域,为夜间遥感在轨定标精度的提升奠定技术基础。

    Abstract:

    Traditional ground object spectrometers have high requirements for optical signal intensity and can only be used during the day but cannot be used at night, which leads to high uncertainty of on-orbit radiometric calibration of remote sensing at night. A technical solution is proposed to enhance the information acquisition capability of the spectrometer under low illumination conditions by directly coupling the traditional spectrometer's CCD (Charge-Coupled Device) detector with the image intensifier. Based on this technology scheme, the spectrometer could effectively measure ground targets' spectral information at night. The experimental results show that the low-level light spectrometer can effectively measure the spectral information of the ground target with good and stable performance under the condition of moonlight and starlight. And the spectrometer can be applied to night remote sensing calibration, night target spectral information acquisition, and other application fields, laying a technical foundation for improving the accuracy of night remote sensing calibration in orbit.

    参考文献
    相似文献
    引证文献
引用本文

张宇,崔皓东,张曦,高彩霞,钱永刚,马灵玲,邱实.夜间遥感场地替代定标的微光光谱仪设计与试验分析[J].半导体光电,2022,43(6):1155-1161. ZHANG Yu, CUI Haodong, ZHANG Xi, GAO Caixia, QIAN Yonggang, MA Lingling, QIU Shi. Design and Experimental Analysis of Low-level Light Spectrometer for Nighttime Remote Sensing Sites Vicarious Calibration[J].,2022,43(6):1155-1161.

复制
分享
文章指标
  • 点击次数:
  • 下载次数:
  • HTML阅读次数:
  • 引用次数:
历史
  • 收稿日期:2022-02-21
  • 最后修改日期:
  • 录用日期:
  • 在线发布日期: 2023-02-07
  • 出版日期:
文章二维码

漂浮通知

①《半导体光电》新近入编《中文核心期刊要目总览》2023年版(即第10版),这是本刊自1992年以来连续第10次被《中文核心期刊要目总览》收录。
②目前,《半导体光电》已入编四个最新版高质量科技期刊分级目录,它们分别是中国电子学会《电子技术、通信技术领域高质量科技期刊分级目录》(T3)、中国图象图形学学会《图像图形领域高质量科技期刊分级目录》(T3)、中国电工技术学会《电气工程领域高质量科技期刊分级目录》(T3)和中国照明学会《照明领域高质量科技期刊分级目录》(T2)。
③关于用户登录弱密码必须强制调整的说明
④《半导体光电》微信公众号“半导体光电期刊”已开通,欢迎关注